Be assured of a quality product and a quality service with AIS. Every AIS Cyclone ships with a 3-year warranty as standard.
- Regulation dependant hourly burn rate of up to *50kg / 110lbs or *105kg / 232 lbs and a large load capacity of up to 1180kg / 2602 lbs, the AIS 0132 Cyclone allows for the bio-secure disposal of your animal-by-product waste in the shortest time possible.
- Suited for a wide range of larger animal carcasses and animal-by-products generated across the agricultural sector including; Pigs & Sows, Dairy / Beef Cattle, Abattoirs, Slaughterhouses, Rendering Operations, Meat Processors, Equine.
- Easy to load via a manually operated roller lid located on the top of the incinerator, giving full access to a large main burning chamber. This ensures users can load the machine via skid loaders and tractor buckets.
- PLC timer controls with automatic burner shut off function and fast ignition burners. Two burners are in the main chamber, one additional burner is in the secondary chamber.
- Can be loaded whilst in operation maximizing the inherent thermal efficiency of our monolithic concrete lining, keeping running costs low.
- Ash doors, fitted as standard, this allows the user to safely remove ash whilst the machine is in operation, so you can keep on loading and burning your waste, saving time.
- Optional Extra Features include; Stack Extension / Ash Rake / USB Data Logger /Heat Exchanger / Control Panel screen size increase / Service Kits.
Engineered for the daily duty cycle.
The AIS 0132 Cyclone is hand-built in the UK or U.S. with a monolithic concrete refractory lining, temperature-controlled burners, and a PLC control system.
- Capacity
- 1180 kg / 2602 lbs
- Burn rate (approx.)
- 105 kg/hr
- Fuel
- Diesel / LPG / Natural Gas
- Refractory
- Monolithic concrete lining
- Loading
- Top-loading
- Controls
- PLC with auto burner shut-off
- Warranty
- 3 years standard
- Build
- Hand-built UK & US
Highlights
- Standard ash door
- Continuous loading
- Industrial PLC controls
Optional extras
AIS 0132 Cyclone — dimensions & performance
| Specification | Metric | Imperial |
|---|---|---|
| Burn Rate | Up to 50 (UK) / 105 (ROW) kg/hr | Up to 110 (UK) / 232 (ROW) lbs/hr |
| Front / Top Load | Top | Top |
| Static Operational Dimensions (LxWxH) | 4.5 x 3.7 x 3.5 m | 14' 9" x 12' x 11' 6" feet/inch |
| External Height - Static | 3500 mm inc. Stack | 11' 6" feet/inch inc. Stack |
| External Height - Static | 2300 mm ex. Stack | 7' 7" feet/inch ex. Stack |
| Weight | 6.2 Tonne estimated | 13669 lbs estimated |
| Load Height from Ground (floor to bottom edge) | 1250 mm | 4' 1" feet/inch |
| Fuel Consumption Diesel | 18.6 – 28.3 LPH est during main burn | 4.9 - 7.5 GPH est during main burn |
| Fuel Consumption LPG | 27 - 42 LPH est during main burn | 6.3 - 11.2 GPH est during main burn |
| Fuel Consumption Nat Gas | 19 - 28 m³/h est during main burn | 656 - 999 ft³/h est during main burn |
| Grate Bars | No | No |
| Load Door Opening (Width x Height/Depth) | 2200 x 1800 mm area | 7' 3" x 5' 11" ft/inch area |
| Chamber Size (LxWxH) | 1.8 x 2.2 x 1.1 m | 5' 10" x 7' 2" x 3' 7" ft/inch |
| Chamber Actual Volume | 3.85 m³ | 136 ft³ |
| Chamber Load Volume | 2.13 m³ | 75 ft³ |
| Chamber Load Capacity | 1180 kg | 2602 lbs |
| Std Stack Diameter | 14" inch/mm 2D Size | 14" inch/mm 2D Size |
| No. Main Burners | 2 | 2 |
| No. Secondary Burners | 1 | 1 |
| Burner Output | 245 kW heat | 835,975 Btu heat |
| Electric Consumption | 0.5 kW electricity | 0.5 kW electricity |
* Burn rates, fuel consumption, weights and chamber capacities are estimates and depend on load type, moisture content, and operating conditions. Contact us for site-specific guidance.
AIS 0132 Cyclone — frequently asked questions
What can the AIS 0132 Cyclone incinerate?+
The AIS 0132 Cyclone is designed for on-site disposal of fallen stock and animal by-products, including poultry, swine, lambs, calves and mixed agricultural waste. Suitability is confirmed against the applicable local requirements for each installation.
What is the capacity and fuel type?+
Load capacity is approximately 1180 kg per cycle, running on Diesel / LPG / Natural Gas. Burn rate varies with load type, moisture and operating conditions.
What combustion standard does the AIS 0132 Cyclone meet?+
Every AIS Cyclone incorporates an integral secondary chamber designed to maintain at least 850 °C for a minimum two-second residence time. AIS supplies documentation to support approval against the applicable local regulations in each destination market.
What warranty is included?+
Every AIS Cyclone ships with a 3-year warranty as standard, covering the chamber, refractory and burner assembly under normal operating conditions.
Do you offer servicing and spares?+
Yes. AIS provides UK-wide servicing, thermocouple replacement, refractory repairs and a full spare-parts catalog for every AIS Cyclone model.
Talk to us about the AIS 0132 Cyclone.
Behind the AIS brand is a real team of experts. Tell us about your operation and we'll come back with the right configuration and the price.
Request a quote