small class · Diesel / LPG / Natural Gas

AIS 033 Cyclone

Step-up capacity for daily on-site mortality.

AIS 033 Cyclone
Capacity
330 kg
728 lbs
Burn rate
50
kg / hour
Fuel
Diesel / LPG / Natural Gas
—
Burner output
159 kW
542,531 Btu
Request a quote
AIS 033 Cyclone Information

What it does, and who it's for.

Be assured of a quality product and a quality service with AIS. Every AIS Cyclone ships with a 3-year warranty as standard.

  • This model is available as a static incinerator or mobile system.
  • Suited for larger pig operations such as finishing farms, full access to the main chamber ensures users can load the machine via skid loaders and tractor buckets.
  • The AIS 033 Cyclone is recognized for also being able to deal with other animal-by-products generated across the agricultural sector including; Poultry, Ewes, Lambs, Game Farms, Estates, Butchers and Farm shops, and is ideal for those looking for a quick, effective and bio-secure animal-by-product incineration solution.
  • Access to the main chamber is via a Top Loading counterbalance lid.
  • PLC timer controls with automatic burner shut off function and fast ignition burners. One temperature-controlled burner in the main chamber and one in the secondary chamber.
  • Burns up to *50kgs/110 lbs per hour.
  • Load capacity of up to 330kg / 728 lbs.
  • Can be loaded whilst in operation maximizing the inherent thermal efficiency of our trusted monolithic concrete lining, keeping running costs low.
  • Optional Extra features include; Grate Bars / USB Data Logger / Ash Door / Stack Extensions / Ash Rake / Simple Heat Exchange system / Control Panel screen size increase / Service Kits .
At a glance

Engineered for the daily duty cycle.

The AIS 033 Cyclone is hand-built in the UK or U.S. with a monolithic concrete refractory lining, temperature-controlled burners, and a PLC control system.

Capacity
330 kg / 728 lbs
Burn rate (approx.)
50 kg/hr
Fuel
Diesel / LPG / Natural Gas
Refractory
Monolithic concrete lining
Loading
Top-loading
Controls
PLC with auto burner shut-off
Warranty
3 years standard
Build
Hand-built UK & US

Highlights

  • Heat-exchange option
  • Service kits available
  • Touch-screen control panel

Optional extras

Grate BarsUSB Data LoggerAsh DoorStack ExtensionsAsh RakeHeat ExchangeLarger Control PanelService Kits
Full specification

AIS 033 Cyclone — dimensions & performance

SpecificationMetricImperial
Burn RateUp to 50 kg/hrUp to 110 lbs/hr
Front / Top LoadTopTop
Operational Dimensions Static (LxWxH)3.3 x 1.9 x 3.5 m10' 9" x 6' 1" x 11' 4" feet/inch
External Height Static3450 mm inc. Stack11' 4" feet/inch inc. Stack
External Height Static2430 mm ex. Stack8' feet/inch ex. Stack
Weight Static2.5 Tonne estimated5512 lbs estimated
Load Height from Ground (floor to bottom edge)925 mm3' feet/inch
Fuel Consumption Diesel7– 10 LPH est during main burn1.8 – 2.7 GPH est during main burn
Fuel Consumption LPG9- 15 LPH est during main burn1.7 – 4.1 GPH est during main burn
Fuel Consumption Nat Gas7- 10 m³/h est during main burn240 – 366 ft³/h est during main burn
Grate BarsOptionalOptional
Load Door Opening (Width x Height/Depth)1595 x 800 mm area5' 3" x 2' 7" ft/inch area
Chamber Size (LxWxH)1.8x 0.8 x 0.7 m6' 1" x 2' 6" x 2' 4" ft/inch
Chamber Actual Volume0.95 m³34 ft³
Chamber Load Volume0.59 m³21 ft³
Chamber Load Capacity330 kg728 lbs
Std Stack Diameter10" inch/mm 2D Size10" inch/mm 2D Size
No. Main Burners11
No. Secondary Burners11
Burner Output159 kW heat542,531 Btu heat
Electric Consumption0.25 kW electricity0.25 kW electricity

* Burn rates, fuel consumption, weights and chamber capacities are estimates and depend on load type, moisture content, and operating conditions. Contact us for site-specific guidance.

FAQ

AIS 033 Cyclone — frequently asked questions

What can the AIS 033 Cyclone incinerate?+

The AIS 033 Cyclone is designed for on-site disposal of fallen stock and animal by-products, including poultry, swine, lambs, calves and mixed agricultural waste. Suitability is confirmed against the applicable local requirements for each installation.

What is the capacity and fuel type?+

Load capacity is approximately 330 kg per cycle, running on Diesel / LPG / Natural Gas. Burn rate varies with load type, moisture and operating conditions.

What combustion standard does the AIS 033 Cyclone meet?+

Every AIS Cyclone incorporates an integral secondary chamber designed to maintain at least 850 °C for a minimum two-second residence time. AIS supplies documentation to support approval against the applicable local regulations in each destination market.

What warranty is included?+

Every AIS Cyclone ships with a 3-year warranty as standard, covering the chamber, refractory and burner assembly under normal operating conditions.

Do you offer servicing and spares?+

Yes. AIS provides UK-wide servicing, thermocouple replacement, refractory repairs and a full spare-parts catalog for every AIS Cyclone model.

Talk to us about the AIS 033 Cyclone.

Behind the AIS brand is a real team of experts. Tell us about your operation and we'll come back with the right configuration and the price.

Request a quote