large class · Diesel / LPG / Natural Gas

AIS 1250 Cyclone

Bio-secure, regular disposal in the shortest time possible.

AIS 1250 Cyclone
Capacity
1,290 kg
2,844 lbs
Burn rate
300
kg / hour
Fuel
Diesel / LPG / Natural Gas
—
Burner output
486 kW
1,658,301 Btu
Request a quote
AIS 1250 Cyclone Information

What it does, and who it's for.

Be assured of a quality product and a quality service with AIS. Every AIS Cyclone ships with a 3-year warranty as standard.

  • This model is available as a Static, Mobile or Transportable incinerator.
  • Suited for a wide range of animal carcasses and animal-by-products generated across the agricultural sector including; Pigs & Sows, Poultry, Dairy / Beef Cattle, Abattoirs, Slaughterhouses, Rendering Operations, Meat Processors, Sheep.
  • Easy to load via a manually operated slide Open/Close lid located on the top of the incinerator, giving full access to a large main burning chamber.
  • PLC timer controls with automatic burner shut off function and fast ignition burners. Three burners are in the main chamber, with one above the grate bars and two below the grate bars. One additional burner is in the secondary chamber.
  • Unique market leading grate bar technology for fast and complete incineration.
  • With a *High burn rate of up to 300kg/661 lbs per hour and a load capacity of up to 1290kg / 2844 lbs this allows for the bio-secure, regular disposal of your waste in the shortest time possible.
  • Can be loaded whilst in operation maximizing the inherent thermal efficiency of our monolithic concrete lining, keeping running costs low.
  • Ash doors, as standard, allows the user to safely remove ash whilst the machine is in operation, so you can keep on loading and burning your waste, saving time.
  • Optional Extra features include; Automated Open / Close Lid / Stack Extension / Ash Rake / USB Data Logger / Heat Exchanger / Control Panel screen size increase / Service Kits.
At a glance

Engineered for the daily duty cycle.

The AIS 1250 Cyclone is hand-built in the UK or U.S. with a monolithic concrete refractory lining, temperature-controlled burners, and a PLC control system.

Capacity
1290 kg / 2844 lbs
Burn rate (approx.)
300 kg/hr
Fuel
Diesel / LPG / Natural Gas
Refractory
Monolithic concrete lining
Loading
Top-loading
Controls
PLC with auto burner shut-off
Warranty
3 years standard
Build
Hand-built UK & US

Highlights

  • Ash doors as standard
  • Loadable during operation
  • Monolithic concrete lining

Optional extras

Grate BarsUSB Data LoggerAsh DoorStack ExtensionsAsh RakeHeat ExchangeLarger Control PanelService Kits
Full specification

AIS 1250 Cyclone — dimensions & performance

SpecificationMetricImperial
Burn RateUp to 300 kg/hrUp to 661 lbs/hr
Front / Top LoadTopTop
Static Operational Dimensions (LxWxH)4.6 x 2.8 x 4.9 m15' x 9' 4" x 15' 11" feet/inch
External Height - Static4857 mm inc. Stack15' 11" feet/inch inc. Stack
External Height - Static2754 mm ex. Stack9' feet/inch ex. Stack
Weight9.5 Tonne estimated20944 lbs estimated
Load Height from Ground (floor to bottom edge)1750 mm5' 9" feet/inch
Fuel Consumption Diesel19 - 28 LPH est during main burn4.9 - 7.5 GPH est during main burn
Fuel Consumption LPG27 - 42 LPH est during main burn6.3 - 11.2 GPH est during main burn
Fuel Consumption Nat Gas19 - 28 m³/h est during main burn656 - 999 ft³/h est during main burn
Grate Bars2020
Load Door Opening (Width x Height/Depth)1335 x 1900 mm area4' 5" x 6' 3" ft/inch area
Chamber Size (LxWxH)1.3 x 1.9 x (1.5 - 2.1) m4' 5" x 6' 3" (4' 11"- 7' 3") ft/inch
Chamber Actual Volume3.80 m³134 ft³
Chamber Load Volume2.33 m³82 ft³
Chamber Load Capacity1290 kg2844 lbs
Std Stack Diameter540mm inch/mm 2D Size540mm inch/mm 2D Size
No. Main Burners33
No. Secondary Burners11
Burner Output486 kW heat1,658,301 Btu heat
Electric Consumption1.2 kW electricity1.2 kW electricity

* Burn rates, fuel consumption, weights and chamber capacities are estimates and depend on load type, moisture content, and operating conditions. Contact us for site-specific guidance.

FAQ

AIS 1250 Cyclone — frequently asked questions

What can the AIS 1250 Cyclone incinerate?+

The AIS 1250 Cyclone is designed for on-site disposal of fallen stock and animal by-products, including poultry, swine, lambs, calves and mixed agricultural waste. Suitability is confirmed against the applicable local requirements for each installation.

What is the capacity and fuel type?+

Load capacity is approximately 1290 kg per cycle, running on Diesel / LPG / Natural Gas. Burn rate varies with load type, moisture and operating conditions.

What combustion standard does the AIS 1250 Cyclone meet?+

Every AIS Cyclone incorporates an integral secondary chamber designed to maintain at least 850 °C for a minimum two-second residence time. AIS supplies documentation to support approval against the applicable local regulations in each destination market.

What warranty is included?+

Every AIS Cyclone ships with a 3-year warranty as standard, covering the chamber, refractory and burner assembly under normal operating conditions.

Do you offer servicing and spares?+

Yes. AIS provides UK-wide servicing, thermocouple replacement, refractory repairs and a full spare-parts catalog for every AIS Cyclone model.

Talk to us about the AIS 1250 Cyclone.

Behind the AIS brand is a real team of experts. Tell us about your operation and we'll come back with the right configuration and the price.

Request a quote