large class · Diesel / LPG / Natural Gas

AIS 0206 Cyclone

Large-frame Cyclone for continuous bio-secure disposal.

AIS 0206 Cyclone
Capacity
1,300 kg
2,867 lbs
Burn rate
50
kg / hour
Fuel
Diesel / LPG / Natural Gas
—
Burner output
188 kW
641,483 Btu
Request a quote
AIS 0206 Cyclone Information

What it does, and who it's for.

Be assured of a quality product and a quality service with AIS. Every AIS Cyclone ships with a 3-year warranty as standard.

  • With a large load capacity of up to 1300kg / 2867 lbs and an hourly burn rate of up to 50kg / 110 lbs, the AIS 0206 Cyclone incinerator is suited for the bio-secure disposal of a wide range of larger animal carcasses generated across the agricultural sector including but not limited to; Dairy / Beef Cattle, Pigs & Sows, Equine Cremation.
  • A curved lid that is opened via a manual sliding action along a frame, gives full access to a large main burning chamber.
  • The Bed of the AIS 0206 is low down and easy to load carcasses into via skid loaders and tractor buckets. The low height of the bed also makes it easy for de-ashing.
  • PLC timer controls with automatic burner shut off function and fast ignition burners. One burner is in the main chamber, one additional burner is in the secondary chamber.
  • Can be loaded whilst in operation maximizing the inherent thermal efficiency of our monolithic concrete lining, keeping running costs low.
  • Optional Extra Features include; Stack Extension / Ash Rake / Inspection Door / USB Data Logger/ Heat Exchanger / Control Panel screen size increase / Service Kits.
At a glance

Engineered for the daily duty cycle.

The AIS 0206 Cyclone is hand-built in the UK or U.S. with a monolithic concrete refractory lining, temperature-controlled burners, and a PLC control system.

Capacity
1300 kg / 2867 lbs
Burn rate (approx.)
50 kg/hr
Fuel
Diesel / LPG / Natural Gas
Refractory
Monolithic concrete lining
Loading
Top-loading
Controls
PLC with auto burner shut-off
Warranty
3 years standard
Build
Hand-built UK & US

Highlights

  • Continuous loading
  • Bio-secure disposal
  • Heavy-frame construction

Optional extras

Grate BarsUSB Data LoggerAsh DoorStack ExtensionsAsh RakeHeat ExchangeLarger Control PanelService Kits
Full specification

AIS 0206 Cyclone — dimensions & performance

SpecificationMetricImperial
Burn RateUp to 50 kg/hrUp to 110 lbs/hr
Front / Top LoadTopTop
Static Operational Dimensions (LxWxH)8.5 x 2.2 x 5.0 m27' 11" x 7' 1" x 16' 3" feet/inch
External Height - Static4950 mm inc. Stack16' 3" feet/inch inc. Stack
External Height - Static2560 mm ex. Stack8' 5" feet/inch ex. Stack
Weight6.6 Tonne estimated14551 lbs estimated
Load Height from Ground (floor to bottom edge)500 mm1' 8" feet/inch
Fuel Consumption Diesel11.8 – 17.9 LPH est during main burn3.1 – 4.7 GPH est during main burn
Fuel Consumption LPG17 - 27 LPH est during main burn3.7 – 7.1 GPH est during main burn
Fuel Consumption Nat Gas12 - 18 m³/h est during main burn416 - 634 ft³/h est during main burn
Grate BarsNoNo
Load Door Opening (Width x Height/Depth)3100 x 1700 mm area10' 2" x 5' 7" ft/inch area
Chamber Size (LxWxH)3.1 x 1.7 x 1.3 m10' 2" x 5' 7" x 4' 1" ft/inch
Chamber Actual Volume5.75 m³203 ft³
Chamber Load Volume2.36 m³83 ft³
Chamber Load Capacity1300 kg2867 lbs
Std Stack Diameter14" inch/mm 2D Size14" inch/mm 2D Size
No. Main Burners11
No. Secondary Burners11
Burner Output188 kW heat641,483 Btu heat
Electric Consumption0.25 kW electricity0.25 kW electricity

* Burn rates, fuel consumption, weights and chamber capacities are estimates and depend on load type, moisture content, and operating conditions. Contact us for site-specific guidance.

FAQ

AIS 0206 Cyclone — frequently asked questions

What can the AIS 0206 Cyclone incinerate?+

The AIS 0206 Cyclone is designed for on-site disposal of fallen stock and animal by-products, including poultry, swine, lambs, calves and mixed agricultural waste. Suitability is confirmed against the applicable local requirements for each installation.

What is the capacity and fuel type?+

Load capacity is approximately 1300 kg per cycle, running on Diesel / LPG / Natural Gas. Burn rate varies with load type, moisture and operating conditions.

What combustion standard does the AIS 0206 Cyclone meet?+

Every AIS Cyclone incorporates an integral secondary chamber designed to maintain at least 850 °C for a minimum two-second residence time. AIS supplies documentation to support approval against the applicable local regulations in each destination market.

What warranty is included?+

Every AIS Cyclone ships with a 3-year warranty as standard, covering the chamber, refractory and burner assembly under normal operating conditions.

Do you offer servicing and spares?+

Yes. AIS provides UK-wide servicing, thermocouple replacement, refractory repairs and a full spare-parts catalog for every AIS Cyclone model.

Talk to us about the AIS 0206 Cyclone.

Behind the AIS brand is a real team of experts. Tell us about your operation and we'll come back with the right configuration and the price.

Request a quote