AIS 064 Cyclone
Capacity
570 kg
1,257 lbs
Burn rate
50
kg / hour
Fuel
Diesel / LPG / Natural Gas
—
Burner output
193 kW
658,543 Btu
Request a quote
AIS 064 Cyclone Information

What it does, and who it's for.

Be assured of a quality product and a quality service with AIS. Every AIS Cyclone ships with a 3-year warranty as standard.

  • Suited for Pig Operations that are looking for a bio-secure, effective incineration solution that can easily manage large Pig carcasses. The AIS 064 Cyclone can also handle other animal-by-products generated across the agricultural sector including small size; Meat Processors / Renderers, Slaughterhouses.
  • Full access to the main chamber via a top loading counterbalance lid ensures users can load the machine via skid loaders and tractor buckets.
  • Burns up to *50kg / 110lbs per hour.
  • Load capacity of up to 570 kg/1257 Ibs.
  • PLC timer controls with automatic burner shut off function and fast ignition burners. Two temperature-controlled burners in the main chamber and one in the secondary chamber.
  • Can be loaded whilst in operation maximizing the inherent thermal efficiency of our trusted monolithic concrete lining, keeping running costs low.
  • Ash door, as standard, allows the user to safely remove ash whilst the machine is in operation, so you can keep on loading and burning your waste, saving time.
  • Optional Extra features include; USB Data Logger / Stack Extensions / Ash Rake / Simple Heat Exchange system / Control Panel screen size increase / Service Kits.
At a glance

Engineered for the daily duty cycle.

The AIS 064 Cyclone is hand-built in the UK or U.S. with a monolithic concrete refractory lining, temperature-controlled burners, and a PLC control system.

Capacity
570 kg / 1257 lbs
Burn rate (approx.)
50 kg/hr
Fuel
Diesel / LPG / Natural Gas
Refractory
Monolithic concrete lining
Loading
Top-loading
Controls
PLC with auto burner shut-off
Warranty
3 years standard
Build
Hand-built UK & US

Highlights

  • Reinforced load chamber
  • Trusted monolithic lining
  • Service kits & extensions

Optional extras

Grate BarsUSB Data LoggerAsh DoorStack ExtensionsAsh RakeHeat ExchangeLarger Control PanelService Kits
Full specification

AIS 064 Cyclone — dimensions & performance

SpecificationMetricImperial
Burn RateUp to 50 kg/hrUp to 110 lbs/hr
Front / Top LoadTopTop
Operational Dimensions (LxWxH)3.1 x 2.8 x 3.4 m10' 2" x 9' 2" x 11' 2" feet/inch
External Height3400 mm inc. Stack11' 2" feet/inch inc. Stack
External Height2050 mm ex. Stack6' 9" feet/inch ex. Stack
Weight2.95 Tonne estimated6504 lbs estimated
Load Height from Ground (floor to bottom edge)1230 mm4' feet/inch recommended
Fuel Consumption Diesel7.9 – 12.1 LPH est during main burn2.1 – 3.2 GPH est during main burn
Fuel Consumption LPG11 - 18 LPH est during main burn2.1 – 4.8 GPH est during main burn
Fuel Consumption Nat Gas8 - 12 m³/h est during main burn280 – 426 ft³/h est during main burn
Grate BarsNoNo
Load Door Opening (Width x Height/Depth)2175 x 880 mm area7' 2" x 2' 11" ft/inch area
Chamber Size (LxWxH)2.2 x 0.9 x 1.1 m7' 2" x 2' 11" x 3' 7" ft/inch
Chamber Actual Volume2.00 m³71 ft³
Chamber Load Volume1.02 m³36 ft³
Chamber Load Capacity570 kg1257 lbs
Std Stack Diameter14" inch/mm 2D Size14" inch/mm 2D Size
No. Main Burners22
No. Secondary Burners11
Burner Output193 kW heat658,543 Btu heat
Electric Consumption0.3 kW electricity0.3 kW electricity

* Burn rates, fuel consumption, weights and chamber capacities are estimates and depend on load type, moisture content, and operating conditions. Contact us for site-specific guidance.

FAQ

AIS 064 Cyclone — frequently asked questions

What can the AIS 064 Cyclone incinerate?+

The AIS 064 Cyclone is designed for on-site disposal of fallen stock and animal by-products, including poultry, swine, lambs, calves and mixed agricultural waste. Suitability is confirmed against the applicable local requirements for each installation.

What is the capacity and fuel type?+

Load capacity is approximately 570 kg per cycle, running on Diesel / LPG / Natural Gas. Burn rate varies with load type, moisture and operating conditions.

What combustion standard does the AIS 064 Cyclone meet?+

Every AIS Cyclone incorporates an integral secondary chamber designed to maintain at least 850 °C for a minimum two-second residence time. AIS supplies documentation to support approval against the applicable local regulations in each destination market.

What warranty is included?+

Every AIS Cyclone ships with a 3-year warranty as standard, covering the chamber, refractory and burner assembly under normal operating conditions.

Do you offer servicing and spares?+

Yes. AIS provides UK-wide servicing, thermocouple replacement, refractory repairs and a full spare-parts catalog for every AIS Cyclone model.

Talk to us about the AIS 064 Cyclone.

Behind the AIS brand is a real team of experts. Tell us about your operation and we'll come back with the right configuration and the price.

Request a quote